dmy@lab
|
44fbced194
|
1.把模拟电荷法的地线加上了
2.初始半径太小时数值性差,接近奇异
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-10-09 10:51:34 +08:00 |
dmy@lab
|
209832e593
|
单独加了地线的计算代码,结果比较接近了。
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-10-08 18:10:39 +08:00 |
dmy@lab
|
2ac1e54f69
|
基本完成逐次镜像法
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-10-08 14:01:55 +08:00 |
dmy@lab
|
3a73dfd84e
|
添加电场计算
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-24 16:20:22 +08:00 |
dmy@lab
|
152ee0a213
|
可以算多相
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-24 14:38:43 +08:00 |
dmy@lab
|
eea457bae4
|
可以达到0.01%的精度
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-23 20:11:25 +08:00 |
dmy@lab
|
0bfd04b415
|
继续排除一些bug
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-23 19:37:52 +08:00 |
dmy@lab
|
da85b45e7e
|
1.修复了坐标对齐的bug
2.修复了迭代步长增加的bug
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-23 19:02:32 +08:00 |
dmy@lab
|
d17ed3632d
|
1.加了计算完成提示
2.改了误差统计方法
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-23 18:21:22 +08:00 |
dmy@lab
|
798c0e1142
|
完成了迭代部分
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-19 15:22:49 +08:00 |
dmy@lab
|
bff2235efe
|
写出一个最简单的自适应法
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-19 14:55:57 +08:00 |
dmy@lab
|
df66a759aa
|
写自适应模拟电荷法
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-18 16:49:55 +08:00 |
dmy@lab
|
2ad26b0a31
|
按《同杆并架多回线下方的电场强度和感应电压》 做,想和“设计手册”例题2-1比较,做了一半没有继续下去。
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-09-18 13:16:16 +08:00 |
dmy@lab
|
0e7f2af5d1
|
已完成。双回路220kV。
Signed-off-by: dmy@lab <dmy@lab.com>
|
2015-08-20 08:53:06 +08:00 |