2020-06-28 13:39:18 +08:00
|
|
|
|
loop_end = 1000000 # 最大循环次数
|
2020-06-27 21:12:13 +08:00
|
|
|
|
# 架线时的状态
|
|
|
|
|
|
# 取外过无风
|
|
|
|
|
|
string_length = 9.2 # 串长 单位m
|
|
|
|
|
|
string_g = 60 * 9.8 # 串重 单位N
|
|
|
|
|
|
t_m = 15 # 导线架设时的气温。单位°C
|
|
|
|
|
|
t_e = 20 # 架线时考虑初伸长的降温,取正值。单位°C
|
|
|
|
|
|
alpha = 0.0000155 # 导线膨胀系数 1/°C
|
|
|
|
|
|
elastic = 95900 # 弹性系数 N/mm2
|
|
|
|
|
|
area = 154.48 # 导线面积 mm2
|
|
|
|
|
|
lambda_m = 14.8129 / area # 导线比载 N/(m.mm)
|
|
|
|
|
|
# 取400m代表档距下
|
|
|
|
|
|
sigma_m = 28517 / area # 架线时,初伸长未释放前的最低点水平应力。单位N/mm2
|
2020-06-28 13:39:18 +08:00
|
|
|
|
span_count = 4 # 几个档距
|
2020-06-27 21:12:13 +08:00
|
|
|
|
# n个档距,n-1个直线塔
|
2020-06-28 13:39:18 +08:00
|
|
|
|
h_array = [0, 0, 0, 0]
|
|
|
|
|
|
l_array = [200, 300, 1400, 500]
|
|
|
|
|
|
t_array = [15, 15, 15, 15]
|
|
|
|
|
|
epslon = 1e-3 # 收敛判据
|