2022-08-22 16:09:08 +08:00
|
|
|
|
# # loop_end = 10000000 # 最大循环次数
|
|
|
|
|
|
# loop_end = 1000000 # 最大循环次数
|
|
|
|
|
|
# # 架线时的状态
|
|
|
|
|
|
# # 取外过无风
|
|
|
|
|
|
# string_length = 9.2 # 串长 单位m
|
|
|
|
|
|
# string_g = 60 * 9.8 # 串重 单位N
|
|
|
|
|
|
# t_m = 15 # 导线架设时的气温。单位°C
|
|
|
|
|
|
# t_e = 20 # 架线时考虑初伸长的降温,取正值。单位°C
|
|
|
|
|
|
# alpha = 0.0000155 # 导线膨胀系数 1/°C
|
|
|
|
|
|
# elastic = 95900 # 弹性系数 N/mm2
|
|
|
|
|
|
# area = 154.48 # 导线面积 mm2
|
|
|
|
|
|
# lambda_m = 14.8129 / area # 导线比载 N/(m.mm)
|
|
|
|
|
|
# lambda_i_array = [
|
|
|
|
|
|
# lambda_m * 0.9,
|
|
|
|
|
|
# lambda_m * 1.2,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m * 0.9,
|
|
|
|
|
|
# lambda_m * 1.5,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m,
|
|
|
|
|
|
# lambda_m * 0.9,
|
|
|
|
|
|
# lambda_m * 1.3,
|
|
|
|
|
|
# ]
|
|
|
|
|
|
# # 取400m代表档距下
|
|
|
|
|
|
# sigma_m = 28517 / area # 架线时,初伸长未释放前的最低点水平应力。单位N/mm2
|
|
|
|
|
|
# span_count = 14 # 几个档距
|
|
|
|
|
|
# # n个档距,n-1个直线塔
|
|
|
|
|
|
# h_array = [
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# 0,
|
|
|
|
|
|
# ]
|
|
|
|
|
|
# l_array = [
|
|
|
|
|
|
# 400,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 500,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 400,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 500,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 500,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# 400,
|
|
|
|
|
|
# 300,
|
|
|
|
|
|
# ]
|
|
|
|
|
|
# t = 15
|
|
|
|
|
|
# epsilon = 1e-4 # 收敛判据
|
|
|
|
|
|
# conductor_n = 6 # 导线分裂数
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
loop_end = 5000000 # 最大循环次数
|
2020-06-27 21:12:13 +08:00
|
|
|
|
# 架线时的状态
|
|
|
|
|
|
# 取外过无风
|
2022-08-22 16:09:08 +08:00
|
|
|
|
string_length = 0.5 # 串长 单位m
|
|
|
|
|
|
string_g = 30 * 9.8 # 串重 单位N
|
|
|
|
|
|
t_m = -25 # 导线架设时的气温。单位°C
|
|
|
|
|
|
t_e = 0 # 架线时考虑初伸长的降温,取正值。单位°C
|
2020-06-27 21:12:13 +08:00
|
|
|
|
alpha = 0.0000155 # 导线膨胀系数 1/°C
|
|
|
|
|
|
elastic = 95900 # 弹性系数 N/mm2
|
|
|
|
|
|
area = 154.48 # 导线面积 mm2
|
2022-08-22 16:09:08 +08:00
|
|
|
|
lambda_m = 7.3256 / area # 导线比载 N/(m.mm)
|
2020-12-14 10:31:29 +08:00
|
|
|
|
lambda_i_array = [
|
2022-08-22 16:09:08 +08:00
|
|
|
|
14.7012 / area,
|
|
|
|
|
|
14.7012 / area,
|
|
|
|
|
|
14.7012 / area,
|
|
|
|
|
|
8.8007 / area,
|
|
|
|
|
|
14.7012 / area,
|
|
|
|
|
|
14.7012 / area,
|
|
|
|
|
|
14.7012 / area,
|
2020-12-14 10:31:29 +08:00
|
|
|
|
]
|
2020-06-27 21:12:13 +08:00
|
|
|
|
# 取400m代表档距下
|
2022-08-22 16:09:08 +08:00
|
|
|
|
sigma_m = 17449 / area # 架线时,初伸长未释放前的最低点水平应力。单位N/mm2
|
|
|
|
|
|
span_count = 7 # 几个档距
|
2020-06-27 21:12:13 +08:00
|
|
|
|
# n个档距,n-1个直线塔
|
2020-12-14 10:31:29 +08:00
|
|
|
|
h_array = [
|
|
|
|
|
|
0,
|
|
|
|
|
|
0,
|
|
|
|
|
|
0,
|
|
|
|
|
|
0,
|
|
|
|
|
|
0,
|
|
|
|
|
|
0,
|
|
|
|
|
|
0,
|
2020-12-14 16:05:17 +08:00
|
|
|
|
]
|
|
|
|
|
|
l_array = [
|
2022-08-22 16:09:08 +08:00
|
|
|
|
703,
|
|
|
|
|
|
720,
|
|
|
|
|
|
587,
|
|
|
|
|
|
620,
|
|
|
|
|
|
539,
|
|
|
|
|
|
450,
|
|
|
|
|
|
611,
|
2020-12-14 10:31:29 +08:00
|
|
|
|
]
|
2022-08-22 16:09:08 +08:00
|
|
|
|
t = 40
|
2020-12-13 16:57:48 +08:00
|
|
|
|
epsilon = 1e-4 # 收敛判据
|
2022-08-22 16:09:08 +08:00
|
|
|
|
conductor_n = 1 # 导线分裂数
|